FTIR Multi-Gas Analyzer MIR FT
FTIR analyzer in a turnkey cabinet for the measurement of up to 50 parameters, to be selected according to the application. MCERTs certified
Based on the FTIR technology (Fourier Transform Infrared) for simultaneous measurement of: HCl, HF, NH3, NO, NO2, N2O, SO2, CO, CH4, TOC, H2O, CO2, O2…
Features & Benefits
- 180°C heated sample line / measurement cell (in association with HOFI sampling system according to the application), ensuring no sample loss or composition changes
- Turnkey system including Industrial PC with Windows based eSAM FT software for on-board data acquisition and processing
- TOC measurement by FID possible, using the complementary Graphite 52M analyzer
- Ideal for measuring trace concentrations in wet, corrosive gas streams
- Suited for hot wet measurements of soluble gases such as HCl, HF, NH3, etc.
- All in one system including industrial PC & software for on-board data acquisition and processing
Main applications
- Municipal, Industrial, Hospital waste incinerators
- Biomass, Cement Kilns, Pulp & Paper, Glass Plants
- DeNOx (SNCR, SCR) applications
- Power & Combustion
Measurable parameters |
Pollutant |
Range |
HCI |
0-15 / 500 |
HF |
0-3 / 100 |
NO |
0-200 / 2000 |
NO2 |
0-200 / 2000 |
N2O |
0-100 / 500 |
NOx |
0-200 / 2000 |
SO2 |
0-75 / 20000 |
CO |
0-75 / 10000 |
CH4 |
0-15 / 1000 |
THC |
0-50 / 1000 |
NH3 |
0-15 / 500 |
H2O(%) |
0-30 / 40 |
CO2(%) |
0-10 / 30 |
O2(%) |
0-10 / 25 |
Lowest / Highest available ranges expressed in mg/m3 (may vary with your site conditions to be indicated on the Site Survey Form)
Technical Specifications |
QAL1 to EN 15267-3 certified |
YES |
US EPA compliance |
YES |
Sampling technology |
Hot/Wet Extraction |
Sample transfert |
180°C heated sampling line |
back flush function |
YES |
span injection |
YES on analyser or at sample point |
Built-In O2 option |
YES |
Serial link communication |
/ |
Other Communication |
Ethernet |
Analogue OUTPUTS |
Optional |
Analogue INPUTS |
Optional |
Dimensions (mm) |
19” rack: 616 x 483 x 220 (DxWxH) |
Approvals & Certifications
- COMPLIANCE WITH IED 2010 APPLICATIONS
- QAL 1 certified by the MCERTs to EN 15267-3
- MCERTs QAL 1 certified gas monitor
- Sira MC 040031/11
- QAL3 compliance as defined by EN 14181
- U.S. EPA approved as compliant with 40 CFR 60 ET 75
- Certified by the Korean NIER
The MIR 9000 multi-gas CEMS offer compliance with EU Regulation IED (WID / LCPD / MCP directive) BREF Incineration, US EPA (40 CFR 60 & 75)
- QAL 1 certified by the TÜV and the MCERTs to EN 15267
- 0000024158 MCERTs QAL 1 certified gas monitorSira MC020010/13
- QAL3 compliance as defined by EN 14181
- U.S. EPA approved as compliant with 40 CFR 60 ET 75
Documentation
ENVEA_MIR_FT_analyzer_multi_gas_ftir_analyzer_EN
ENVEA_Process_Catalogue_EN
envea_catalogue_cems_emission-monitoring_en